Product Detail :
|
1) servicing & reconditioning transformer cooling fans at 66/11kv shidlaghatta muss in tl&ss division chintamani. i 2) for replacement of voltmeters, ammeters and megawatt meters at 66/11kv muss cheemangala in tl&ss division chintamani. 3) for supply of stationeries to pertaining to nodal-1 & 2 sub-station in tl&ss division chintamani. 4) supply of maintenance materials for 66/11kv muss m. gollahalli, in tl&ss division chintamani. 5) requirement of 1 no of 11kv outdoor polycrete feeder ct pertaining to 66/11kv muss yenigadale in tl&ss division chintamani. 6) supply of maintenance materials for the fy 2019-20 to 66/11kv muss talagawara in nodal-1 in tl&ss division chintamani. 7) supplying of 11kv 400a gos contacts and 11kv pedestal insulators at 66/11kv sis chintamani in nodal-1 in tl&ss division chintamani. 8) supply of essential maintenance materials for the 3" quarter of the year 2019-20 to 220kv rs chintamani in tl&ss division chintamani. 9) supplying and fixing of copper flats, nct power terminal connector, g flat and wooden clamps to 20mva power transformer 1 at 66/11kv muss iragamapalli in tl&ss division chintamani. 10) refilling of existing fire extinguishers pertaining to 66/11kv s/s chintamani in tl&ss division chintamani. 11) refilling of existing fire extinguishers pertaining to 220kv r/s chintamani in tl&ss division chintamani. 12) refilling of existing fire extinguishers pertaining to 66/11kv ganjugunte in tl&ss division chintamani. 13) supply and fixing of additional jumps with copper lugs and pg clamps at 66/11kv substation chintamani in tl&ss division chintamani. 14) for replacement of ammeters, megawatt meters and mvar meters in the various 66kv c&r panel available at 66/11kv muss talagawarain tl&ss division chintamani. 15) repairing of 66kv outgoing julpalya line annunciator of c&r panel at 66/11kv muss sadali 16) requirement of 11 kv outdoor three numbers of bank 1 cts (ratio 400-800/1-1-1a) pertaining to 66/11kv muss mgollahalli. 17) replacement of annunciator of 66kv control panels at 220kv r/s chintamani. 18) replacement of burnt out acdb spare parts and 100mva power transformer-1 cooling circuit spares at 220kv r/s chintamani. 19) oil leakage arresting of power transformer-2 at 66/11kv muss cheemangala in tl&ss division chintamani. 20) oil leakage arresting of power transformer at 66/11kv sis chintamani in tl&ss division chintamani. 21) regarding- supplying one number of 66kv class 1200a female bus gos contacts to incoming 66kv chintamani line at 66/11kv muss talagawara in tl&ss division chintamani.
|